Product Comparison & Recommended Uses

This page combines product information and the supplied BORPAINT product materials. Use the table to identify the appropriate component of the five-product system for walls, roofs, fire protection, insulation plaster and surface preparation.

5 Products, 1 Solution

Compare the complete BORPAINT system.

Technical values below are reproduced as product-material specifications. Energy-saving results depend on application thickness, surface condition and building characteristics.

ProductPrimary UseBest Application AreasThermalWater / MoistureFireBreathableApplication MethodKey Technical / Performance Notes
BORPAINTBORPAINTMineral thermal insulation paintInterior & exterior thermal insulation paintInterior walls, exterior walls, façades; functional insulation layer before/with finish systemYesWaterproofing: YesFire-retardantYesRoller or brush; 2 coats; about 4 hours between coats; primer recommendedEnergy saving up to 50%; density 1.20 g/mL; solids 67%; pH 8.96; matt; interior consumption ~0.8 kg/m², exterior ~1.0 kg/m²; touch-dry ~1 hr; full cure ~72 hrs.
BORFIREPROOFBORFIREPROOFBoron mineral fire-resistant paintFire-critical structural and safety zonesStructural steel, load-bearing elements, escape routes, stair cores, emergency exits, walls, ceilings, façades, roofs, pipes, air ducts, boiler rooms, public and industrial buildingsThermal supportSurface protectionUp to 120 min; ~1450°C average; A2-s1,d0 reportedYesBrush, roller or suitable sprayer; 2–3 coats; 4 hrs between coatsWater-based; matt; density 1.30 g/mL; consumption ~1 kg/m² for 2 coats; touch-dry ~1 hr; full cure ~72 hrs; 5/10/18 kg packaging; 24-month sealed shelf life.
BORROOFBORROOFRoof thermal & waterproof insulationFlat and sloped roof insulationConcrete roofs, metal roofs, membrane & shingle roofs, factory and warehouse roofs, commercial, hotel, office and prefab buildings0.021 W/mK stated100% waterproofing statedFire-retardantYesPrime; apply at least 2 perpendicular coats; protect from water/load for 24 hrs; full cure ~72 hrsEnergy saving up to 50%; density 1.23 g/mL; solids 65%; pH 8.99; matt; ~0.8 kg/m² per coat; 10 & 18 kg packaging; 24-month sealed shelf life.
BORSTUCCOBORSTUCCOMineral thermal insulation plasterInsulation and leveling before final paintInterior & exterior walls and ceilings, new masonry, concrete walls, partitions, façades requiring added insulationLow conductivity; insulation supportMoisture controlFire resistance: YesYesTrowel; one or more layers depending on surface condition; primer recommendedEnergy saving up to 50% when used as part of system; sound damping: Yes; smooth paint-ready finish; water-based; natural off-white.
BORPRIMERBORPRIMERUniversal acrylic primerSurface preparation and adhesion controlInterior & exterior porous surfaces before BORPAINT, BORROOF, BORSTUCCO or BORFIREPROOF as specifiedRegulates absorptionYesBrush or roller; approx. 1:7 dilution with water; touch-dry ~1 hr; ready for coating ~4 hrsWater-based universal acrylic primer; improves adhesion and equalizes surface absorption; transparent/milky white and dries clear.

Walls & Façades

Use BORPRIMER for preparation, BORSTUCCO where a leveling/insulating plaster layer is needed, and BORPAINT as the mineral thermal insulation paint layer.

Roofs

BORROOF is the dedicated roof thermal and waterproof coating. The materials identify concrete, metal, membrane, shingle, factory, warehouse and commercial roofs as suitable applications.

Fire-Critical Areas

BORFIREPROOF is the dedicated mineral fire-resistant coating for structural and safety zones. Refer to the reports page for the supplied TSE and CEKAM documentation.